Remote-Control CommandsGPS and Assisted GPS
134Operating Manual 1171.5248.12 ─ 15
Example:
BB:GPS:TRIG:SOUR OBAS
sets for path A the internal trigger executed by the trigger signal
from the second path (path B).
BB:GPS:TRIG:OBAS:DEL 50
sets a delay of 50 chips for the trigger.
[:SOURce<hw>]:BB:GPS:TRIGger:OBASeband:INHibit <Inhibit>
Specifies the number of chips by which a restart is to be inhibited following a trigger event.
Applies only for triggering by the second path (two-path instruments only).
Parameters:
<Inhibit> float
Range: 0 to 2^32-1
Increment: 1 chip
*RST: 0 chips
Example:
BB:GPS:TRIG:SOUR OBAS
sets for path A the internal trigger executed by the trigger signal
from the second path (path B).
BB:GPS:TRIG:INH 200
sets a restart inhibit for 200 chips following a trigger event.
[:SOURce<hw>]:BB:GPS:TRIGger:RMODe?
Queries the current status of signal generation for all trigger modes with GPS modulation
on.
Return values:
<Rmode> STOP | RUN
RUN
the signal is generated. A trigger event occurred in the triggered
mode.
STOP
the signal is not generated. A trigger event did not occur in the
triggered modes, or signal generation was stopped by the com-
mand :BB:GPS:TRIG:ARM:EXECute (armed trigger modes
only).
Example:
BB:GPS:TRIG:MODE ARET
selects the "Armed_Retrigger" mode.
BB:GPS:TRIG:SOUR EXT
sets external triggering via the TRIGGER 1 connector.
BB:GPS:TRIG:RMOD?
queries the current status of signal generation.
Response: RUN
the signal is generated, an external trigger was executed.
Usage: Query only
Trigger Settings